Smart PV Controller SUN200012_15_17_20KTL-M2
AI Powered Arcing Protection
Up to 30% More Energy with Optimizer
WLAN, Fast Ethernet, 4G Communication Supported
Input your details to have a sales representative reach out
- Technical Details
- Downloads
SUN2000 -15KTL-M2
SUN2000 -17KTL-M2
SUN2000 -20KTL-M2
Efficiency `
98.5 %
98.65%
98.65%
98.65%
98.00%
98.30%
98.30%
98.30%
Input
Recommended max. PV power 1
18,000 Wp
22,500 Wp
25,500 Wp
30,000 Wp
1,080V
160 V ~ 950 V
200 V
660 V
22 A
30 A
Number of MPP trackers
2
Max. input number per MPP tracker
2
Output
Grid connection
Rated Output Power
3,000 W
15,000 W
17,000 W
20,000 W
Max. apparent power
13,200 VA
16,500 VA
18,700 VA
22,000 VA
Rated output voltage
220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W + N + PE
Rated AC grid frequency
50 Hz / 60 Hz
Adjustable power factor
0.8 leading … 0.8 lagging
Max. output current
20 A
25.2 A
28.5 A
33.5 A
Max. total harmonic distortion
≤ 3 %
Features & Protections
Input-side disconnection device
Yes
Anti-Islanding protection
Yes
AC over-current protection
Yes
AC short-circuit protection
Yes
AC over-voltage protection
Yes
DC reverse-polarity protection
TYPE IIÂ
DC surge protection
Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
AC surge protection
Yes
Residual current monitoring unit
Yes
Arc fault protection
Yes
Ripple receiver control
Yes
Integrated PID recovery 4
Yes
General Data
Operating temperature range
-25 ~ + 60 °C (-13 °F ~ 140 °F)
Relative operating humidity
0 %RH~100 %RH
Operating altitude
0 ~ 4,000 m (13,123 ft.) (Derating above 2000 m)
Cooling
Natural convection
Display
LED Indicators; Integrated WLAN + FusionSolar App
Communication
RS485; WLAN/Ethernet via Smart Dongle-WLAN-FE; 4G / 3G / 2G via Smart Dongle-4GÂ
(Optional)
Weight (incl. mounting bracket)
25kg
Dimension (incl. mounting bracket)
525 x 470 x 262 mm (20.7 x 18.5 x 10.3 inch)
Degree of protection
IP65
Nighttime Power Consumption
< 5.5 W 6
Optimizer Compatibility
DC MBUS compatible optimizer
SUN2000-450W-P
Standard Compliance (more available upon request)
Certificate
EN/IEC 62109-1, EN/IEC 62109-2
Grid connection standards
G98, G99, EN 50549, CEI 0-21, CEI 0-16, VDE-AR-N-4105, VDE-AR-N-4110, AS 4777.2, C10/11, ABNT, VFR 2019, RD 1699, RD 661, PO 12.3, TOR D4, IEC61727, IEC62116, DEWA
- Inverter max input PV power is 40,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers.
- The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.
- Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
- SUN2000-12~20KTL-M2 raises potential between PV- and ground to above zero through integrated PID recovery function to recover module degradation from PID. Supported module types include: P-type (mono, poly).
- Â <10 W when PID recovery function is activated.